NOMA®WOOL ALU / CLIMATUBE® WOOL 1m Ø 35 x 20mm GEG 50%
Breakdown of dimensions: Example: 15-20mm-> 15 mm pipe diameter x 20 mm insulation thickness
NOMA®WOOL ALU (CLIMATUBE® WOOL) stone wool insulation shells with surface coating of grid-reinforced aluminum foil.
The insulation shells are slit on one side and have a self-adhesive, overlapping adhesive strip for easy installation.
The fire-resistant pipe insulation can be used for heating and domestic water systems, pipe, air conditioning and ventilation lines, and solar lines.
Please observe the installation guideline!
Material: Stone wool insulation shell with surface coating of grid-reinforced aluminum foil
Over time, there is no change in the fire behavior of mineral wool.
Over time, there is no change in the thermal conductivity of mineral wool.
Length: 1 meter
Fire classification: A2Ls1d0 (EN 13501-1)
Color: silver
Thermal conductivity:
< 40 mm:
0, 034 W/mK at 10°C
0, 037 W/mK at 40°C
0, 055 W/mK at 150°C
> 40 mm:
0, 035 W/mK at 10°C
0, 038 W/mK at 40°C
0, 055 W/mK at 150°C
Fire behavior:
A2L s1 d0 (non-combustible)
Temperature range:
up to 0°C to +250°C
Melting temperature >1000°C
Reference | A* | B* | Length | Box Content |
15 - 20 | 15mm | 20mm | 1 m | 42 m |
18 - 20 | 18mm | 20mm | 1 m | 42 m |
22 - 20 | 22mm | 20mm | 1 m | 36 m |
28 - 20 | 28mm | 20mm | 1 m | 30 m |
35 - 20 | 35mm | 20mm | 1 m | 25 m |
42 - 20 | 42mm | 20mm | 1 m | 20 m |
48 - 20 | 48mm | 20mm | 1 m | 20 m |
60 - 20 | 60mm | 20mm | 1 m | 15 m |
* see photo
Cold water pipes DIN 1988 200 or without requirements
50 % GEG
-Pipes and fittings in wall and ceiling penetrations, in the crossing area of pipes,
at pipe connection points, at central pipe distributors
-Pipes in components, between heated rooms of different users.
100 % GEG
-Pipes in unheated rooms and in basement rooms
-Pipes in exterior walls as well as in building structures between unheated rooms, in channels and shafts
-Pipes for supplying multiple parties
-Hot water pipes
-Hot water pipes up to a water content of 3 liters, which are neither included in the circulation circuit
nor equipped with electric trace heating (branch lines) and are located in heated rooms. (*)
*) Although no requirements are set here, insulation must be provided for the following reasons:
Corrosion protection, avoidance of cracking and flow noises, air and structure-borne sound insulation, reduction of heat load.
To maintain user comfort, the hot water pipe should be insulated to prevent unnecessary cooling by components, etc.