NOMA®WOOL ALU / CLIMATUBE® WOOL 1m Ø 35 x 20mm GEG 50%

 

Breakdown of dimensions: Example: 15-20mm-> 15 mm pipe diameter x 20 mm insulation thickness

NOMA®WOOL ALU (CLIMATUBE® WOOL) stone wool insulation shells with surface coating of grid-reinforced aluminum foil.
The insulation shells are slit on one side and have a self-adhesive, overlapping adhesive strip for easy installation.
The fire-resistant pipe insulation can be used for heating and domestic water systems, pipe, air conditioning and ventilation lines, and solar lines.
Please observe the installation guideline!

Material: Stone wool insulation shell with surface coating of grid-reinforced aluminum foil
                 Over time, there is no change in the fire behavior of mineral wool.
                 Over time, there is no change in the thermal conductivity of mineral wool.
Length: 1 meter
Fire classification: A2Ls1d0 (EN 13501-1)
Color: silver

Thermal conductivity:
< 40 mm:
    0, 034 W/mK at 10°C
    0, 037 W/mK at 40°C
    0, 055 W/mK at 150°C

> 40 mm:
    0, 035 W/mK at 10°C
    0, 038 W/mK at 40°C
    0, 055 W/mK at 150°C

Fire behavior:
A2L s1 d0 (non-combustible)

Temperature range:
up to 0°C to +250°C
Melting temperature >1000°C

 


 

Reference A* B* Length Box Content
15 - 20 15mm  20mm 1 m 42 m
18 - 20 18mm 20mm 1 m 42 m
22 - 20 22mm 20mm 1 m 36 m
28 - 20 28mm 20mm 1 m 30 m
35 - 20  35mm 20mm 1 m 25 m
42 - 20  42mm 20mm 1 m 20 m
48 - 20 48mm 20mm 1 m 20 m
60 - 20  60mm 20mm 1 m 15 m

* see photo
 

 



Cold water pipes DIN 1988 200 or without requirements
50 % GEG
-Pipes and fittings in wall and ceiling penetrations, in the crossing area of pipes,
 at pipe connection points, at central pipe distributors
-Pipes in components, between heated rooms of different users.

 



100 % GEG

-Pipes in unheated rooms and in basement rooms
-Pipes in exterior walls as well as in building structures between unheated rooms, in channels and shafts
-Pipes for supplying multiple parties
-Hot water pipes
-Hot water pipes up to a water content of 3 liters, which are neither included in the circulation circuit
 nor equipped with electric trace heating (branch lines) and are located in heated rooms. (*)
*) Although no requirements are set here, insulation must be provided for the following reasons:
Corrosion protection, avoidance of cracking and flow noises, air and structure-borne sound insulation, reduction of heat load.
To maintain user comfort, the hot water pipe should be insulated to prevent unnecessary cooling by components, etc.

EU-Responsible Name: Andreas Hellwig
EU-Responsible Street: Weiherhausstraße
EU-Responsible House No: 8b
EU-Responsible Post Code: 64646
EU-Responsible Town: Heppenheim
EU-Responsible Country: Germany
EU-Responsible Email: [email protected]
EU-Responsible Phone Number: 49(0)170 7696696
GPSR attachment: Download
Also buy with this product: